Skip to main content
F3D
Giá đỡ từ tính BLTouch cho đầu đùn Micro Swiss NG Direct Dr… 1

3 images

Máy In 3D

Giá đỡ từ tính BLTouch cho đầu đùn Micro Swiss NG Direct Drive v2

Remix of Giá đỡ từ tính BLTouch cho đầu đùn Micro Swiss NG By jbaekey_582169

By jbaekey_582169

Downloads
37
Likes
10
Views
556

Files 3 1 MB

  • Microswiss_NG_BLTouch_Probe_Mount_v2_1766167583.stlSTL · 280.2 KB
  • Microswiss_NG_BLTouch_Gantry_Mount_v2_1766167584.stlSTL · 355.7 KB
  • Microswiss_NG_BLTouch_Probe_Mount_v2_2mm_Offset_1766167585.stlSTL · 414.9 KB

Make a variant with AI

Build another version of this model.

Open Studio

Description

Version Differences

Improvements over the original include:

  • Tighter tolerances 
    Tighter tolerances for less possible motion during probing
  • Optional gantry 
    Optional gantry plate with 2mm of additional height from nozzle.  Given the geometry of the extruder stepper, the probe is also moved an additional 2mm on the X axis.  So add 2 and -2 to your Z an X values in your M851 values or probe offset values in the menu.  For reference my z-offset changed to -0.5.  This puts the probe magnets close to the stepper so make sure the magnets latch on the gantry magnets and not the stepper motor during installation.
  • Magnet Removal Holes
    Holes to remove magnets for when you mess up polarity and have to flip them.
  • Deeper Magnet Holes
    Tap them in with a mallet and large bolt for a tight fit.
  • Wiring Loop
    Wiring loop for….wires

Excerpt from the original version:

Ever have your BLtouch “accidentally” crash into a model or part of your printer?  Me neither….but in case I do and break another BLtouch probe pin or entire probe, I created this magnetic adapter for the Micro Swiss NG Extruder to hold the BLTouch.  The space for the BLTouch probe is minimal and I had to get creative with some of the geometry.

An M48 test yields a 0.00387 standard deviation between probes which is decent.  The filament totals 5g but I do not know the total magnet weight.  It is definitely heavier than the original mount from Thingiverse but it is also has less flex when using PETG.  The original model printed in PLA is stiffer but easy to snap when hijinks ensue.

The mount should work on any printer with similar hole spacing in the gantry plate.

Assembly

  1. When installing ensure that all blobs, seams, and strings are removed from the mating surfaces between printed parts.  Depending on your layer height, you may need to shave the magnet slots for a tight fit.
  2. Once you are sure the magnets will fit, arrange them in a N-S-N one part and S-N-S pole orientation on the other.  This as close to a Halbach array you can get with 3 magnets.  Use super glue if the magnets will not stay in place.
  3. Attach gantry adapter plate to the gantry plate.  The top screw hole is recessed and requires that the m3 bolt be completely within that recess to ensure proper magnet alignment.
  4. Attach BLTouch probe to the Probe Mount part.
  5. Attach BLTouch cable.
  6. Snap into the two parts together and ensure there are no visible gaps by applying some pressure.
  7. Adjust of the Probe Z offset.

Hardware Needed

  • Six 6x2 neodymium round magnets

Print Settings

  • Material:PETG (PLA may work better)
  • Nozzle: 0.6mm
  • Infill: 100%
  • No supports

Rant

Sometimes I wonder if my printer is held together with gum and twine.  I'm sure that I can trace it back to something I did or didn't do but the chaotic experiences between exactly the same prints are annoying.  I've had it all:

  • Motors overheat?  Yep.
  • Z axis stops mid-print (maybe from heating)?  Of course.
  • Model releases from bed and wedges between the frame and hotend/probe?  You wouldn't expect it, but yes.
  • Misconfigured stops cause carriage to crash probe into frame and lead screws when large print attempted?  I can't make this up.
  • Probe fails to deploy causing hotend to try to imprint the nozzle into the glass bed and bend the X axis extrusion?  “I can do this!” is what I imagine my printer saying.
  • Probe strain relief at the hotend damages intermediary connection and causes the nozzle to impersonate a fraking rig?  Oh, you betcha.

Disclaimer:  My printer is not a PRUSA but is still priced in a range where I would expected a better ratio of success to failure.  It has seen some things though….many things.

Read more Show less

Print spec

Formats
stl
Model files
3
Total size
1 MB
Largest file
414.9 KB

0 comments

See all