Skip to main content
F3D
Gá BIQU H2 V2S gọn cho Ender 3 Pro + MicroProbe v2/BL Touch 1

7 images

Máy In 3D

Gá BIQU H2 V2S gọn cho Ender 3 Pro + MicroProbe v2/BL Touch

Remix of Ống dẫn gió làm mát Pudgy BIQU H2 V2S (Dual 5015 Part Cooling Duct) By skybldev_1002855

By scrith

Downloads
247
Likes
38
Views
2,704

Files 6 6.6 MB

  • h2v2s-e3p-backing-plate_1772627537.3mf3MF · 461.9 KB
  • h2v2s-e3p-plate-clamp_1772627539.3mf3MF · 33.9 KB
  • h2v2s-pudgy-dual-5015-remix_1772627539.3mf3MF · 4.8 MB
  • bltouch-2mm-spacer_1772627540.3mf3MF · 20.3 KB

Make a variant with AI

Build another version of this model.

Open Studio

Description

A compact mounting solution for a dual 5015 fan with clear nozzle view, and use of the original metal BL Touch bracket.

I found the Pudgy fan duct and really liked the look of it but found that it could be improved in some areas. Part of the 5015 mounts interfered with the operation of the extruder release lever and I felt that there were more mounting bosses than necessary. I also reduced the size of the heat set inserts from needing M4s to using M3s instead, although this was just for the weight savings.

The mounting bracket is completely my own. It is a 2-part design with hidden wire routing behind the main carriage plate and a clamp that securely connects the extruder to the bracket. The carriage plate mounts using the existing two mounting holes in the Ender 3 Pro x-carriage.

Because of the positioning of the V2S on the plate, the extruder sits in the same X position as the OEM extruder, and as an added benefit the OEM mounting plate for the BL Touch can still be used, although you will need to print a small spacer (provided).

Update December 2024 - STEP files available

I have uploaded a step file of the project for remixing.

Update October 2024 - MicroProbe v2 mounting solution

My BL Touch broke and I replaced it with a BiQu MicroProbe v2, I have designed a bracket for this probe to attache to the existing bottom mounting screw hole. You will need two M2x8 bolts and matching M2 nuts to mount the probe to the bracket with the wire connector facing forward, and a slightly longer M3 bolt to replace the previous bottom mounting bolt.

The bracket holds the probe at the correct distance from the bed and nozzle for the standard H2 V2S so no spacer is needed.

Please post your makes, and comment your suggestions.

Read more Show less

Print spec

Formats
3mfstep
Model files
6
Total size
6.6 MB
Largest file
4.8 MB

0 comments

See all